How to install a surge protector?

**Surge Protector (SPD)**, also known as a **surge arrester**, is a critical device used in AC 50/60Hz power systems with a rated voltage of up to 380V, or in communication systems. It provides protection against overvoltage caused by indirect and direct lightning strikes, as well as other transient voltage surges. Surge protectors are widely applied in residential, commercial, and industrial settings to meet the requirements of surge protection. **1. General Overview** (1) Surge protectors should be selected according to international standards such as IEC 61312, IEC 61643, VDE 0100, and GB50057-94. These standards ensure that the system is designed with proper graded lightning protection, effectively reducing overvoltage to a level that is safe for connected equipment. (2) The choice of power surge protector depends on the type of power grid in the environment, such as TN, TT, or IT systems. Different grid configurations require different types of SPDs to ensure optimal performance. (3) Type B surge protectors are typically installed as the first line of defense at the boundary between Zone 0 and Zone 1 in low-voltage distribution circuits, such as on the low-voltage side of a dedicated transformer or the main power distribution panel. They are designed to protect against overvoltage caused by direct lightning strikes and induced surges on transmission lines. (4) Type C surge protectors are commonly used in multi-stage protection systems to address transient overvoltages resulting from secondary lightning strikes and switching operations. **2. Important Notes** (1) To prevent long-term short circuits due to overload, it is strongly recommended to install a suitable fuse or circuit breaker in series with the surge protector at its input. (2) For unattended locations, it is advisable to choose an SPD with remote monitoring capabilities, allowing for easy tracking of its operational status. **3. Selection Guide** Selecting the right surge protector involves several key steps: (1) Choose the appropriate UC value based on the power supply system and site conditions. (2) Determine the installation location based on the protection distance required by the SPD. (3) Ensure that the SPD does not cause any faults under normal operation and does not interfere with the equipment during a fault. (4) Select the most suitable SPD based on the specific location of installation and the voltage tolerance of the protected equipment. (5) Consider the energy coordination between SPDs at different levels to ensure effective and reliable protection. **Surge Protector Installation Rules** 1. Install the SPD as close as possible to the building entrance to provide early protection. 2. Position the SPD as near as possible to the equipment being protected to minimize the length of the wiring. 3. Keep the SPD connections as short and straight as possible to reduce inductance and improve performance. 4. After installing an SPD1 at the building entrance, place a second SPD2 close to the sensitive equipment for additional protection. 5. At the building entrance, you can use SPDs tested to Class I, II, or III standards. Near the equipment, SPDs tested to Class II or III are usually sufficient. 6. Install the SPD at the boundary of the Lightning Protection Zone (LPZ) to ensure proper zoning and protection strategy. By following these guidelines, you can ensure that your electrical systems are well-protected against damaging voltage surges, providing both safety and reliability.

Polarized Film

Window film

Shenzhen Filmbase Technology Co., Ltd. , https://www.globalfilmbase.com